| SYMPTOM |
DIAGNOSTICS |
SOLUTION |
| Heating
Element (Resistor) Not
Powered |
Check
the correct voltage of the resistor |
Reset
power |
| |
If
the voltage is correct, check the exact polarity
on the leads of the resistor |
Replace
the resistor |
| |
Check
the electrical contacts |
Repair
or replace the contacts |
| |
Reset
and check that the safety thermostat is powered |
Replace
the safety thermostat |
| |
Make
sure that the pressure switch is powered |
Replace
the thermostat |
| |
Where
envisaged, make sure that the power relay is powered |
Replace
the relay |
| |
Incorrect
boiler pressure readout (no steam) |
Check
the anti-vacuum system, replace as required |
| |
Check
the main water supply |
Reset
water |
| |
Make
sure the inlet valve is open |
Open
the inlet valve |
| |
Check
the self-leveling function |
Replace
the self-leveling probe |
| |
Make
sure that the self-leveling probe is powered and that the
internal piston is not obstructed |
If
not, make sure that the appropriate fuse in the main control
unit is working properly, otherwise replace |
| |
Check
the retainer valve |
Clean
the valve and replace the seal |
| Too
Much Water in the Boiler |
Check
the auto-level solenoid for leaks |
Replace
the auto-level solenoid. |
| |
Check
the auto-level solenoid voltage |
If
not working correctly, replace it. If it is working, check
the auto-level probe and the control unit |
| |
Check
the manual filling valve for leaks |
Replace
the valve |
| |
Check
the heat exchanger for leaks |
Replace
the boiler |
| |
Check
the auto-level valve |
Replace
the self-leveling probe |
| SYMPTOM |
DIAGNOSTICS |
SOLUTION |
| Loss
of Water |
Check
the main water supply |
Reset
water |
| |
Make
sure the inlet valve is open |
Open
the water inlet valve |
| Loss
of Power in the Supply Circuit |
Make
sure that the 3-way solenoid is powered |
|
| |
Check
the supply circuit button |
Replace
the main electronic card or the "dashboard" card |
| Physical
Blockage (caused by Deposits or Unusual) |
Check
gigler clamping |
Check
gigler clamping |
| |
Check
the 3-way solenoid support clamping |
Clean
or replace it |
| |
Check
the 3-way solenoid clamping |
Clean
or replace it |
| |
Check
the connection holes between the sprays and the pre-infusion
chamber, the 3-way valve and the gigler |
Clean |
| |
Check
the secondary retainer valve in the coffee circuit |
Replace
it |
| |
Check
the heat exchanger clamping |
Clean
it |
| |
Check
the doser-gigler clamping |
Clean
or replace it |
| Pump |
Make
sure that pressure is correct (7-9 bar) |
Replace
the pump |
| |
Check
pump rotation |
Release
or replace it |
| |
Make
sure the motor is powered |
|
| SYMPTOM |
DIAGNOSTICS |
SOLUTION |
| Continuous
Delivery |
Check
the electrical connections of the doser |
Clean
and reconnect |
| |
|
Replace
the doser. If the doser causes impulses, replace the
electronic control card |
| Inconsistent
Delivery (Long) |
Make
sure that the doser generates impulses |
Replace
the doser. If the doser causes impulses, replace the
electronic card |
| Inconsistent
Supply (Short) |
Check
the expansion valve (neplax) for leaks through the supply unit
during delivery |
Remove,
clean or replace the gasket |
| |
Check
the 3-way valve for leaks through the supply unit during
delivery |
Replace
the 3-way solenoid |
| |
Check
the retainer valve |
Clean
or replace the gasket |
| Too
Slow |
Sprays
blocked |
Replace
them |
| |
Coffee
too light in colour |
Adjust
the grinding (grinder-doser) |
| |
Gigler
clogged |
Clean
or replace it |
| |
Pump
pressure too low |
Adjust
pump pressure (7-9 bar). Replace the pump |
| |
Check
the heat exchanger, the pipes and the gigler for obstructions |
Change
the pipes, clean the heat exchanger with acid, clean the unit,
check the function of the water depurator |
| Too
Fast |
Coffee
doses too small |
Adjust
the coffee dose |
| |
Grinding
too large |
Adjust
the setting of the grinder-doser |
| |
Pump
pressure too high |
Adjust
pump pressure (7-9 bar). Replace the pump |
| Leaks
around the Filter-Holder |
Check
underneath the sheath of the sump |
Replace
it |
| |
Check
the edge of the filter |
Replace
it |
| SYMPTOM |
DIAGNOSTICS |
SOLUTION |
| Delivery
Water Too Cold |
Check
the water economy valve, if fitted |
Adjust
the flow using the knob. Replace it. |
| Water
Leaks from the Coffee Grounds in the Filter-Holder after
Infusion |
Check
the position of the blower (Mac Cup & Program) |
Fit
the blower correctly |
| |
Check
the 3-way solenoid discharge |
Clean
or replace it |
| |
Check
the pipe routing from the sprayers to the 3-way solenoid |
Clean |
| |
Check
the temperature of the unit (external 80-85 °C) |
|
| |
Check
the coffee dose |
Adjust
the coffee dose (grinder-doser) |
| |
Check
the coffee grinding |
Adjust
the setting of the grinder-doser |
| |
Check
the coffee pressing |
Inform
the user about the correct pressure of the coffee dose |